PROFITEST MBASE

Test Instrument for VDE 0100 / IEC 60364.6

A broad-range measuring device allows for use of the test instrument in all alternating and 3-phase electrical systems with voltages from 65 to 500 V and frequencies of 15.4 to 420 Hz.

DESIGN PLUS powered by light & building CE Conformity  Russian Federation Conformity Approval  Russian Federation Type Approval  DAkkS National Accreditation Body of Germany  Measuring Category CAT IV300 V  Measuring Category CAT III500 V

 
  • International Industry Forum Product Design Award EASY transfer to DDS-CAD Loop and line impedance measurement
  • Measurement of insulation resistance using nominal voltage, with variable or rising test voltage
  • Low-resistance measurement
  • Earth resistance measurement
  • Standing-surface insulation measurement
  • Universal connector system
     

 Testing of residual current devices (RCCBs)

  • Measurement of contact voltage without tripping the RCCB.
    Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value.
  • Tripping test with nominal residual current, tripping time measurement
     

Special testing for systems and RCCBs

  • Testing of equipment and RCCBs with rising residual current including indication of tripping current and contact voltage at the moment the RCCB is tripped
  • Testing of RCCBs with: ½ × IΔN, 1× IΔN, 2× IΔN, 5× IΔN
     

Special Features

  • EASY transfer stands for direct incorporation of the Profitest Master into DDS-CAD planning software.
  • Display of approved fuse types for electrical systems
  • Energy meter start-up testing
  • Calculation of cable lengths for common copper wire cross-sections
  • Measurement of biasing, leakage and circulating current up to 1 A, as well as working current up to 150 A with the WZ12C current sensor clamp as an accessory
  • Phase sequence measurement (including highest line-to-line voltage)
  • Measurement of contact voltage without tripping the RCCB.
    Contact voltage is measured with reference to nominal residual current using 1/3 of the nominal residual current value. 
  • Tripping test with nominal residual current, tripping time measurement
     
PROFITEST MBASE  MPRO   MTECH  MXTRA 
    New   New
RCD measurements        
UB measurement without tripping the RCD x x x x
Tripping time measurement x x x x
Tripping current measurement x x x x
Selective, SRCDs, PRCDs, type G/R x x x x
AC/DC sensitive RCDs, types B and B+ - - x x
Testing of insulation monitoring devices (IMDs) - - - x
Testing of residual current monitoring devices (RCMs) - - -- x
Testing for N-PE reversal x x x x
Loop impedance ZL-PE / ZL-N        
Fuse table for systems without RCDs x  x x x
Without tripping the RCD, fuse table -  - x x
With 15 mA test current without tripping the RCD x  x x x
Earth resistance        
Earth resistance RE (mains operation)
I/U measuring method (2/3-wire measuring method
via measuring adapter: 2-wire/2-wire + probe)
x x x x
Earth resistance RE (battery operation)
3 or 4-wire measuring method via PRO-RE adapter
- x - x
Soil resistivity ρE (battery operation) (4-wire measuring method via PRO-RE adapter) - x - x
Selective earth resistance RE (mains operation) with 2-pole adapter, probe, earth electrode and current clamp sensor (3-wire measuring method) x x x x
Selective earth resistance RE (battery operation) with probe, earth electrode and current clamp sensor (4-wire measuring method) via PRO-RE adapter and current clamp sensor) - x - x
Earth loop resistance ρEloop (battery operation) with 2 clamps (current clamp sensor direct and current clamp transformer via PRO-RE/2 adapter) - x - x
Equipotential bonding measurement RLO
with automatic polarity reversal
 x x x x
Insulation resistance RISO
with variable or rising test voltage (ramp)
x  x x x
Variable or rising test voltage x  x x x
Voltage measurement
UL-N / UL-PE / UN-PE / f
x  x x x
Special measurements        
Leakage current (clamp meter measurement) IL, IAMP
Phase sequence
Earth leakage resistance RE(ISO)
Voltage drop
Standing surface insulation ZST
Meter start-up
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Leakage current with PRO-AB adapter - - - x
Residual voltage test - - - x
Intelligent ramp - - - x
Features        
Selectable user interface language x  x x x
Memory (database for up to 50,000 objects) x  x x x
Automatic test sequence function - x - x
RS 232 port for RFID/barcode scanner x  x x x
USB port for data transmission x  x x x
Interface for Bluetooth - - - x
ETC user software for PC x  x x x
Measuring category: CAT III 500 V / CAT IV 300 V x  x x x
DAkkS calibration x  x x x
Article number  M520M M520N M520o M520P
PROFITEST MBASE  MPRO   MTECH  MXTRA 

 

  Article No: M520M
Icon Technical Data » GB » F » I (pdf 704 kB)
Icon Operating Instructions » GB » F » I » E » NL » CZ » P » FI (pdf 1434 kB)
Short-form Operating Instructions D-GB-F-E-I-NL-CZ (pdf 634 kB)
Icon Pamphlet » GB » F  » I  » NL » CZ (pdf 4401 kB)
Flyer PL (pdf 845 kB)
Software ETC
Software PC.doc-WORD/EXCEL
Software PC.doc-ACCESS
Software Driver Control
Software MASTER Updater
Accessories (display)