The flexible 3-phase current sensor is used in combination with MAVOWATT 30,
40, 70 or any measuring
instruments of up to 1,5 V AC measuring input and Hypertronics plug.
The flexible current transformers can be placed around one or several
conductors of any type and design (insulated cable, busbars, pipes).
Internal batteries allow for an independent operation of the measuring
amplifier.
1000 V
- Wide range of applications, 3 measuring ranges 30 A/300 A/3000 A AC
and large bandwidth 10 Hz ... 10 kHz for harmonic analysis
- Simultaneous measurement in all 3 phases
- Precise measurements even with low currents, due to wide dynamic range and
high sensor sensitivity
- Low conductor position influence and minimum stray field influence
- Easy to operate in restricted space thanks to small sensor cross-section
of 9.9 mm and slim end cap of 13.6 mm
- Safe handling even with protection gloves; opening of sensor
and measuring range setting in one-hand operation
- Extremely long battery life of up to 1,000 hours
- External power supply for long-term measurements (optional)
- Current sensor with protection type IP65, measuring amplifier with IP40
- High level of safety for the user, measurement category
1000 V@CATIII, 600 V@CATIV and unlimited overload capacity
| Feature |
Specifications |
| Measuring ranges |
30 A |
300 A |
3000 A |
| Output signal (AC) |
50 mV/A |
5 mV/A |
0,5 mV/A |
| Residual current / ripple |
8 mV eff. |
2 mV eff. |
2 mV eff. |
| Measuring uncertainty (45... 65 Hz) |
±1% ±0,1 A |
±1% ±0,1 A |
±1% ±1 A |
| Overload capacity |
unlimited |
| Linearity |
±0,2% of rdg. |
| Bandwidth |
10 Hz bis 10 kHz (-1 dB) |
| Phase angle error |
< ±1° (45... 65 Hz) |
| Min. load impedance |
100 kΩ for indicated accuracy |
Type
METRAFLEX |
max.
Loop Length |
Article No. |
| 3003XL/24 |
600 mm |
Z207i |
|