The new, multi-talented SMARTCONTROL expands the Energy Control System, which
enjoys widespread use in industrial environments. It unites energy and
consumption data logging for a wide variety of media with peak load optimization,
control functions and error message management. And thus it's not only possible
to monitor consumption, it can be influenced as well. Valuable resources can be
used more efficiently, energy costs can be lastingly reduced and opportunities
provided by modern energy management can be fully exploited.
.
S0 Pulse Inputs
- Acquisition of energy and consumption data, temperatures, switching statuses and process quantities
- Error message management, continuous comparison of characteristic values and indication of errors via switching output, e-mail or SMS
- Peak load management in combinations with switching outputs
- Timer programs and switching of relays after the occurrence of predefined events
- Calculation of mean values and integrals, as well as heat and cold quantities
Versatile Data Collector:
- Meter readings (electrical power, gas, water, heat etc.)
- Temperatures (outside, inside, inlet and return temperature, etc.)
- Statuses (burner and pump on-times etc.)
- Analog signals (signal converters, measuring transducers etc.)
- Data from bus compatible measuring instruments and energy meters
Superb Features:
- Custom tailored scope of functions thanks to modular concept
- Manufacturer independent connection of data sources via analog, digital,
S0 pulse and temperature inputs, as well as universal M-Bus, LON and Modbus
interfaces
- new: Use of LON interfaces without binding or special knowledge
- Synchronized meter reading using the FREEZE command with M-Bus and LON
- Flexible control of processes via analog and switching outputs
- Connection to existing infrastructures via Ethernet TCP/IP or optional
socket modules for analog telephone lines, ISDN, GSM/GPRS or Bluetooth
- Inexpensive creation of networks with standard components
- Easy data exchange via Windows DLL or OPC server
- Exact time with deviation of less than 1 minute per month, automatic
synchronization via time server
- Internal 2 MB flash memory can be expanded with CompactFlash
- Transfer of data and settings to CompactFlash
SMARTCONTROL manager for simple configuration included
- 3 Years Warranty
- Made in Germany
| Type |
Designation |
Article No. |
| SMARTCONTROL |
Standard version, power supply 12…24 V=, Ethernet crossover cable, screwdriver, installation instructions, manual and SMARTCONTROL manager on CD |
U200A |
| SMARTCONTROL IP 65 / 12 V= |
IP 65 control cabinet version with built-in 12 V= power pack, Ethernet crossover cable, screwdriver, installation instructions, manual und SMARTCONTROL manager on CD |
U200B |
| SMARTCONTROL IP 65 / 24 V= |
IP 65 control cabinet version with built-in 24 V= power pack, Ethernet crossover cable, screwdriver, installation instructions, manual und SMARTCONTROL manager on CD |
U200C |
SMARTCONTROL
with IO24 (new) |
IP 65 control cabinet version with built-in 24 V= power pack, Same as
standard version, but additionally with input/output module for 24
channels |
U200D |
SMARTCONTROL
with LON (new) |
Same as standard version, but additionally with LON interface module |
U200E |
SMARTCONTROL
with IO24+LON (new) |
Same as standard version, but additionally with LON interface module |
U200F |
FAQs concerning the SMARTCONTROL
|