The SINEAX V608 converts the measured quantity (i.e. signal from a
thermocouple or a resistance thermometer) into a proportional, analog output
quantity.
- Measured quantity and measuring range can be programmed with a PC:
facilitates planning and project work, short lead-times, minimal inventory
- Integrated cold junction compensation
- Measuring transducer with 2-wire connection for field use in close
proximity to the process
- Measurement output: 4 to 20 mA
- Open-circuit sensor and short-circuit monitoring / defined output
performance in the event of disturbance
- With or without auxiliary power terminals (prog. from 12 to 30V)
- Small and compact for optimized space utilization
- Available with "intrinsically safe" explosion protection per
EEx ia
IIC T6
- Serial interface
- K17 housing for top-hat rail mounting
| Article No. |
Variant |
|
141515 |
Standard, without electrical isolation |
|
141523 |
EEx ia IIC T6, without electrical isolation |
Order other variants with complete order code 608-8... in
accordance with the data sheet. See data sheet for default configuration.
|