| 1.  | USB X-TRA | Interface Adapter Infrared to USB for METRAHit E, S Series, X-TRA |
| 2.  | Z3431-2 | High Frequency Probe, 100kHz - 750MHz, 0.25..50V AC |
| 3.  | Z3409 | Pt 100 Sensor for Surface and Immersion Measurements |
| 4.  | TS-Chipset | Pt 100 Temperature Sensors, adhesive, -50°.. +550°C |
| 5.  | TF220 | Pt 1000 Immersion Probe for Measurements in Gas and Liquid |
| 6.  | TF550 | Pt 100 Immersion Probe for Measurements from -50°... +550°C |
| 7.  | TF400CAR | Pt 1000 dipstick oil temperature sensor for motor oil temperature measurement in automotive applications |
| 8.  | F836 | Ever-ready Case for METRAHit with Cable Compartment |
| 9.  | HitBag | Cordura Belt Pouch for METRAHIT and METRAport |
| 10.  | F829 | Carrying Pouch for METRAHit |
| 11.  | F840 | Ever-ready Case for 2 METRAHit, 2 Adapters + Accessories |
| 12.  | HC20 | Hard Case for 1 METRAHit and Accessories |
| 13.  | HC30 | Hard Case for 2 METRAHit and Accessories |
| 14.  | Fuses | Fuses for Multimeters |
| 15.  | Z13B | Current Transformer Clamp 0,5-60/600ADC; 0,2-40/400AAC, 10mV/A; 1mV/A, 1,5%; 2%, 50mm Ø |
| 16.  | WZ11B | Current Sensor Clamp, 0.5 ..20 / ..200AAC, adjustable |
| 17.  | WZ12B | Current Sensor Clamp, 10mA ... 100AAC, 100mV/A, ±2% |
| 18.  | WZ12C | Current Sensor Clamp, 1mA ..15A / ..150AAC, adjustable |
| 19.  | Z3512A | Current Sensor Clamp 1/10/100/1000 AAC, selectable |
| 20.  | AF101A | Flexible Current Sensor 0,5..1000/10kA:1V, 1-0,1mV/A, Loop Length 1200mm, 1%VAusg.+2mV |
| 21.  | WZ12A | Current Transformer Clamp with Cable, 15...180AAC, 1mA/A, ±3% |
| 22.  | WZ12D | Current Transformer Clamp, 30mA ... 150AAC, 1000:1, 1mA/A, ±2,5% |
| 23.  | WZ11A | Current Transformer Clamp, 1...200AAC, 1mA/A, 1..3% |
| 24.  | Z3511 | Current Transformer Clamp, 4 ... 500 AAC, 1 mA/A, 3% |
| 25.  | Z3512 | Current Transformer Clamp, 0.5 ... 1000 AAC, 1 mA/A, 0.5 ... 0.7% |
| 26.  | Z3514 | Current Transformer Clamp, 1.. 2000AAC, 1mA/A, 0,5%+0,1A |
| 27.  | NA X-TRA | Power adapter 90 ... 250 VAC / 5 VDC for METRAHIT X-TRA |
| 28.  | GH X-TRA | Protective Rubber Cover and Carrying Strap for METRAHIT BASE, PRO, X-TRA |
| 29.  | SM16 | Current Measuring Adapter |
| 30.  | Z206D | Quick Charger for NiMH Batteries |
| 31.  | Z206E | Rechargeable batteries for potentially explosive atmospheres |
| 32.  | KS17-2 | Cable Set, max. 16 A, 1000 V / CAT III, Length 1.30 m |
| 33.  | KY95-2 | Alligator Clips (1 Pair) for KS17-2 |
| 34.  | KS17S | Cable set with 2 mm Ø steel tips and 120 cm cable, 1000 V / CAT II |
| 35.  | KY94 | Hook Clips (1 Pair) for KS17-2 |
| 36.  | KS17-ONE | Cable Set, max. 16 A, 600 V / CAT III, Length 1.30 m |
| 37.  | KY95-1 | Alligator Clips (1 Pair) for KS17-ONE |
| 38.  | KY96 | Plug-On Lugs (1 Pair) for KS17-2 |
| 39.  | NW3A | Shunt resistor 3A, 0.1 Ω class 0,5 600V CAT.IV, 100mV/A |
| 40.  | NW300mA | Shunt resistor 300mA, 0.1Ω, class 0,5; 1mV/mA |
| 41.  | KS-NTS | Cable Set with Different Test Probes, max. 20 A, 1000 V CAT III |
| 42.  | METRAFLEX 3000 | Flexible Current Sensor 30/300/3000 A, Loop length 610mm |
| 43.  | TF400SURFACE | Surface Temperature Sensor, Type K Thermocouple |
| 44.  | METRAFLEX P300 | Flexible Current Sensor 3/30/300 A, 1V-10mV/A, Loop length 450 mm |
| 45.  | CP30 | AC/DC Current Sensor Clamp with Voltage Output for Multimeters, 30A, 25mm Ø (new) |
| 46.  | CP330 | AC/DC Current Sensor Clamp with Voltage Output for Multimeters, 300A, 25mm Ø (new) |
| 47.  | CP1100 | AC/DC Current Sensor Clamp with Voltage Output for Multimeters, 1000A, 32mm Ø (new) |
| 48.  | METRAFLEX 3000M | Flexible Current Sensor 30/300/3000 A, 100-1mV/A, Loop length 160mm (new) |
| 49.  | Z3431-3 | Temperature Probe with Immersion Sensor, NiCr-Ni, -20.. +350°C |
| 50.  | Z3431-4 | Temperature Probe without Sensor, NiCr-Ni, -25.. +1150°C |
| 51.  | Z3431-9 | Temperature Probe without Sensor, NiCr-Ni, -20.. +350°C |
| 52.  | HIT CLIP | Magnetic Holder and Belt Strap for METRAHIT Multimeters with Rubber Holster (new) |
| 53.  | METRAFLEX 3001 | Flexible Current Sensor 30/300/3000 A, 100-1mV/A, Loop length 610mm |